Instrumentation for EMC testing and measurement
Description
The EMC Lab boasts a wide selection of instrumentation and software tools for basic and applied EMC research, including:
Semi-anechoic chamber
- Size 7.5 m x 4 m x 3.3 m, for measurements up to 3 m in the frequency range 26 MHz – 40 GHz.
- Anechoic covering by ferrites and absorbers. Full-compliance performances for radiated immunity and pre-compliance performances for radiated emissions.
- Turntable diameter 1.5 m, max weigh 500 kg, with optic link for remote control.
- Antenna mast with manual height positioning and pneumatic polarization.
- Filtered supply three-phase and single-phase ac 32 A.
- Optic Ethernet datalink
Measurement automation
- Software ETS-Lindgren TILE!
- Controller ETS-Lindgren EM Center.
- Controller EMCO CO3000 (turntable).
Measurement chain for radiated emissions
- EMI Receiver Keysight MXE N9038B, 3 Hz – 26.5 GHz.
- Loop Antenna EMCO 6509, 1 kHz – 30 MHz.
- Biconical Antenna ETS-Lindgren 3110C, 30 MHz – 300 MHz.
- Log-Periodic Antenna ETS-Lindgren 3148B, 200 MHz – 2 GHz.
- Horn Antenna ETS-Lindgren 3117, 1GHz -18 GHz.
Measurement chain for radiated immunity
- Instrumentation update in progress
Network and Spectrum Analyzers
- Vector Network Analyzer Keysight ENA E5080B, 9 kHz - 6.5 GHz, four ports, with electronic calibration device.
- Vector Network Analyzer Keysight ENA E5061B, 5 Hz – 1.5 GHz, two ports, additional gain-phase ports and setup for impedance analysis.
- Handheld Spectrum Analyzer Keysight FieldFox N9913A, 30 kHz - 4 GHz.
Arbitrary Waveform Generator
- Keysight M8190A, 5 GHz, 12 Gsa/s.
Oscilloscopes
- Keysight MXR604A, 6 GHz, 16 Gsa/s
- Keysight DSOX1204G, 200 MHz, 2 Gsa/s
Measurement chain for conducted emissions
- Ad hoc ac supply with three-phase insulation transformer 32 A
- LISN Schwarzbeck nslk8128, three-phase and single-phase 32 A, 9 kHz – 30 MHz
- LISN Messtec AN4032, , three-phase and single-phase 32 A, 9 kHz – 30 MHz
- Pair of LISNs Teseq HV-AN 150 for automotive (CISPR25), military (MIL-STD 461) and airborne (DO-160) equipment.
Injection and monitoring of conducted disturbances
- Electromagnetic Clamp Shaffner KEMZ801, 150 kHz – 230 MHz
- Coupling/Decoupling Network Shaffner M325, three-phase 32 A, 150 kHz- 230 MHz
- Bulk Current Injection probe FCC F-120-2, 10 kHz – 230 MHz
- Tubular Wave Coupler AR BI30413, 400 MHz-3 GHz with calibration fixture
- Monitor Probe Solar 9205-1, 20 Hz – 8 MHz
- Monitor Probe Solar 9123-1N, 10 kHz – 500 MHz
- Calibration Fixture FCC-BCICF-1,10 kHz – 400 MHz
Burst, Surge, Electrostatic Discharges
- Integrated Generator EMTest UCS 500-M with single-phase 16 A CDN
- Capacitive Clamp
- ESD Gun
Static and low-frequency field sensors
- 3-Axis dc Hall magnetometer Metrolab Instruments THM 7025
- Field Analyzer Narda EFA 300, 5 Hz - 32 kHz
Software for electromagnetic simulation
- Ansys (HFSS, Maxwell, etc.) active academic licence on regular basis
- CST Microwave Studio (licence can be activated for specific projects)
- EMSS Feko (licenze can be activated for specific projects)